Mechanical and pneumatic stored energy injures people during routine pit work because it's invisible. A cylinder that fires when you bump a button, or a climber spring that releases when you remove a pin, moves faster than you can pull your hand back.
Pneumatic mistakes:
- Mistake - Working on a charged system. A robot can hold stored air even when 'off.' Touching a fitting or solenoid can fire a cylinder. Fix: before any pneumatic work, open the manual vent plug (FRC rules require an easily accessible manual vent valve that releases all system pressure without tools) and confirm BOTH the storage and working pressure gauges read 0 psi. Inspectors verify that pressure fully vents.
- Mistake - Wrong relief valve or regulator setting (R811 / R808). The compressor relief valve must be set to release at 125 psi (R811), and the working-pressure regulator must be set to 60 psi or less (R808), providing all working pressure. Fix: install/verify the relief valve and regulator before inspection.
- Mistake - Assuming 'off' means 'safe.' It doesn't. Fix: make 'vent to zero' part of your LOTO procedure every time.
Spring and elastic mistakes:
- Mistake - Removing a pin from a loaded climber or intake. Springs and surgical tubing store energy, and R608 governs allowable non-battery energy-storage sources. Pulling a retaining pin can snap a mechanism shut on a hand. Fix: relieve the spring/tubing first - back off tension, support the mechanism, or use a controlled-release tool. Never put fingers in the path of a loaded element.
- Mistake - Raised arm with no support. A raised arm or elevator held only by a motor will drop when power is cut. Fix: lower it or block it before working under it (part of dissipating stored energy in LOTO).
Diagnostic habit: before reaching into any subsystem, ask 'what's still holding energy here?' and answer for all three forms - air, springs/elastic, and gravity-held masses. Vent it, relieve it, or block it, then try to move it by hand to verify it's safe. The teams that get hurt are the ones who skip the 'verify zero energy' step because the fix 'will only take a second.'
the part worth keeping
Key takeaways
- Vent pneumatics to 0 psi on both gauges (manual vent plug) before touching fittings - 'off' is not 'safe.'
- Set the relief valve to 125 psi and the working regulator to 60 psi or less (R811); relieve loaded springs/surgical tubing (R203) before removing pins.
- Block or lower any motor-held raised arm before working under it, then hand-verify zero energy.
SafetyCommon Safety Mistakes & Troubleshootinglesson 4 of 5
Keep going
Take the quiz+10 XP with an accountMore in Common Safety Mistakes & Troubleshooting
where this came from
Sources and corrections
This lesson is AI-assisted: drafted from primary sources, then reviewed and edited by hand. Errors still get through. When one is reported we fix it and write down what changed, in public, in the corrections log.
sources and further reading
clipped to this lesson
Articles that go further on this
The lesson gets you through the topic. These go wider on it, and they read in one sitting.
- 9 min readFRC Pneumatics: How to Design, Wire, and Program a Pneumatic SystemComplete FRC pneumatics guide: components, the REV Pneumatic Hub vs PCM, single vs double solenoids, safe wiring, WPILib programming, and the 60/120 psi limits./blogread it
- 16 min readFRC Elevator and Arm Design: Staging, Rigging, Motors, Gravity, and SafetyA primary-source FRC guide to designing elevators and arms: cascade vs continuous rigging, staging, motor and gear-ratio sizing, gravity math, and safe holding./blogread it
- 13 min readWPILib Won't Deploy: Every Cause and How to Fix ItYour WPILib deploy is failing? Work the decision tree: wrong folder in VS Code, team number, roboRIO image, JDK version, macOS network privacy. Fixes for each./blogread it
answer sheet
Lesson quiz
All 3 right completes the lesson. Miss one and only that question comes back, anything you already answered correctly stays banked.
0 of 3 answered
01Before any pneumatic work, what must you do first to make the system safe?
02What settings are required for the compressor relief valve and the working-pressure regulator?
03Besides venting air, what other stored-energy forms must be neutralized before servicing a robot?
Answer every question to submit.
All 28 lessons in Safetyopenclose
01 / culture-and-roles
02 / ppe-and-shop-safety
03 / battery-pneumatics-electrical
04 / events-and-program
05 / safety-worked-examples-mini-projects
- Not read yet:Mini-Project: A Battery Management & Logging System
- Not read yet:Mini-Project: Write a Robot Lockout/Tagout (LOTO) Procedure
- Not read yet:Worked Example: Current Limits That Prevent Brownouts
- Not read yet:Mini-Project: Assemble a Competition Pit Safety Kit
- Not read yet:Mini-Project: Run a Mock Pit Safety Inspection
06 / safety-common-mistakes-troubleshooting
- Not read yet:Troubleshooting Brownouts and Power Sag
- Not read yet:Battery Handling Mistakes That Cause Injuries and Fires
- Not read yet:Electrical Isolation and Wiring Mistakes Inspectors Fail You For
- Not read yet:Stored-Energy Surprises: Pneumatics and Springs
- Not read yet:Pit and Shop Conduct Mistakes That Hurt Your Judging
07 / safety-advanced-engineering-case-studies